Type | PNG Gas Generator |
Material | Mild Steel |
Fuel Type | Gas |
Capacity | 125 |
Usage/Application | Generator Convertor |
Color | Yellow |
Incepted in the year 1988, at Ghaziabad (Uttar Pradesh, India), we “Gentech Traders & Engg. Works”, are known as the foremost Trader and Supplier of a wide range of Gas and Diesel Generator Sets, Used Generator Sets, Generator Rental Service, AMC Service, Generator Installation Service, Generator Hiring Services, DG Set Overhauling Services, etc. The offered products are manufactured using optimum quality material and advanced technology. These products are highly appreciated by our clients for features like easy installation, energy efficiency, robust construction, trouble free performance and simple maintenance. In order to meet different requirements of clients, we offer these products in various specifications at the most reasonable rates. We have available generators of highly renowned names like Cummins, Mahindra, Leyland and Kirloskar.
REFURBISHED 100 KVA PNG/LPG/CNG GAS Generator Set
Model | PNG |
Brand | Ashok Leyland |
Phase | 3 Phase |
Prime Power Rating kVA / kW | 100KVA/80 KW |
Power Factor | 0.8 (lag) |
Voltage | 415 V |
RPM / Frequency | 1500 / 50 Hz |
Cooling | Water Cooled |
No. of Cylinders | 6 |
Starting System | 12 V Electrical |
Sound Proof Diesel Generating Set
Brand | Escorts |
Power | 40 kVa |
Voltage | 415 V |
Fuel Type | Diesel |
Size | 701 x 600 x 889 mm |
Fuel Consumption At 75 Load | 5.61 ltr. |
Height | 1400 mm |
Weight Net | 322 Kg |
Exhaust Temperature ( DegreeC) | 487 Degree C |
Mean piston speed | 6.35 m/s |
Model | C30D5P |
No. of Phases | 3 Phase |
Frequency (Hz) and RPM | 50 Hz, 1500 RPM |
Features:
- Superior performance
- Less fuel consumption
- Sturdy construction
62.5 kVA Escort Diesel Generator
View Brochure
Brand | Escorts |
Fuel Consumption (at 100% Load) | 14.1 Ltrs |
Fuel Tank Capacity | 150 Ltrs |
Frequency | 50 Hz |
Electrical Battery starting voltage | 12 Volts-DC |
Lube Oil change period | 500 hrs |
Voltage | 230/415 V |
Bore x Stroke | 100 x 120 mm |
Noise Level | < 75 dBA |
Rated Speed | 1500 RPM |
Insulation Class | Class H |
Power Factor | 0.8 lagging |
Prime Rating at rated rpm | 62.5 kVA/ 50 kW |
Governing Class (As per ISO 8528 Part-V) | G2 |
Weight of genset with canopy (approx..)^ Dry | 1420 Kg |
Weight of genset with canopy (approx..)^ Wet | 1550 Kg |
Dimension | 2800*1100*1595 mm |
Engine Model | 4R810TA G1 |
Rated output (Prime Continuous rating as per ISO 8528-1) | 61 KW/ 83 HP |
No. of Cylinder | 4 |
Cubic Capacity | 3.24 Ltrs |
Lube Oil Sump Capacity | 10 Ltrs |
Coolant Capacity | 17.5 Ltrs |
Alternator Efficiency (at 100% load) 0.8 pf** | 91% |
Max Voltage Dip at Full Load 0.8 pf Lag | < 20% Sec |
Max Time to build up rated voltage at Rated RPM | < 5 sec provided engine reach the rated speed |
Condition | Old/Refurbished |
10 kVA Escorts Diesel Generator
Brand | Escorts |
Fuel Consumption (at 100% Load) | 3.00 Ltrs/hr |
Fuel Tank Capacity | 50 Ltrs |
Frequency | 50 Hz |
Prime Rating at rated rpm | 10 kVA/ 8 kW |
Power factor | 0.8 lagging |
Voltage | 230/415 V |
Governing Class (As per ISO 8528 Part-V) | G2 |
Noise Level | < 75 dBA |
Fuel Consumption (at 75% Load) | 2.40 Ltrs/hr |
Fuel Consumption (at 50% Load) | 1.80 Ltrs/hr |
Weight of genset with canopy (approx..)^ Dry | 750 Kg |
Weight of genset with canopy (approx..)^ Wet | 800 Kg |
Dimension | 1760*820*1330 mm |
Electrical Battery Starting Voltage | 12 Volts-DC |
Engine Model | EA16 G1 |
Rated output (Prime Continuous rating as per ISO 8528-1) | 11.8 kW/ 16 HP |
Cooling System | Air |
No. of Cylinder | 2 |
Cubic Capacity | 1.56 Ltrs |
Bore x Stroke | 95 x 110 mm |
Rated Speed | 1500 RPM |
Lube Oil Change Period | 500 hrs |
Lube Oil Sump Capacity | 6.5 Ltrs |
Insulation Class | Class H |
Alternator Efficiency (at 100% load) 0.8 pf** | 82.6% |
Max Voltage Dip at Full Load 0.8 pf Lag | < 20% Sec |
Max Time to build up rated voltage at Rated RPM | < 5 sec provided engine reach the rated speed |
Condition | Old/Refurbished |